SPECIFICATIONS

Part Number: IS200SCTLG1A
Manufacturer: General Electric
Series: Mark VIe
Product type: Static Control Charge Board
Fuse: 120 VDC
Mounting Location: Load Cabinet
Availability: In Stock
Country of Manufacture: United States (USA)

Functional Description

IS200SCTLG1A is a static control charge board developed by GE. It is a part of General Electric Mark VIe control system. The board is most commonly associated with the Mark VIe series, but it can also be associated with the Innovation Series. When used with the Innovation Series, the board will be installed in the Load or Control Cabinet. It performs the function of a static charge control board. When operating any type of electronic system, static charge control and damping are critical considerations. Static electricity buildup can harm electronics and, in extreme cases, can cause explosions or fires. Furthermore, static electricity can be hazardous to technicians working on components. The Mark VIe control was created to serve a wide range of control and protection applications, including steam and gas turbines, as well as power generation balance of plant (BOP) equipment. The control provides more redundancy options, improved maintainability, and increased capability for locating I/O closer to the controlled equipment.

Features

  • There are no potentiometers or LED indicators on this board. The sub-D pin connector on the left side of the board has four pins, while the connector on the right side of the board has three pins. Two blue variable resistors in the bottom right corner of the board operate at a voltage of 250.
  • The SCTL board can operate at three different redundancy levels: single, dual, and triple. When using the board with dual redundant systems, redundant and single input packs with dual IONets will be used to transmit these inputs to the Mark VIe controllers.
  • This board was designed as a printed circuit board (PCB) with no potentiometers on the surface. The card includes two sets of sub-D pin connectors, one with three pins and the other with four pins.
  • The fuse for this component has a rating of 120 VDC and is mounted in the load cabinet

LS2100 Static Starter

  • The LS2100 static starter system uses the generator as a starting motor to start a gas turbine. An integrated static start system is made up of the LS2100 control, the Mark VIe control, and the EX2100 excitation control.
  • The run, torque, and speed setpoint signals are supplied by the Mark VIe control to the LS2100 control, which operates in closed loop control mode to supply variable frequency power to the generator stator. The LS2100 control regulates the field current during startup by controlling the EX2100 control.
  • A CPCI enclosure containing the Mark VIe CPCI controller is housed in the control cabinet. the world, and the world, and the world, and the world, the imagination, and the imagination of the world, the imagination of the world, the imagination of the world.
  • QNX Neutrino is the controller operating system (OS), which was designed for high-speed, high-reliability industrial applications. Temperature inputs and diagnostic variables are handled by the field control I/O.

Product Attributes

  • High performance: The board is designed to provide high performance and reliability, which makes it suitable for use in critical applications.
  • Robust construction: It is built with high-quality materials and designed to withstand harsh environments, ensuring long-term performance and durability.
  • Multiple input/output channels: The board features multiple input/output channels, which provide flexibility and enable it to interface with different components in the control system.
  • Easy maintenance: Designed for easy maintenance, with easily accessible components that can be easily replaced if needed.
  • Developed by GE: Developed by General Electric, a multinational conglomerate known for its expertise in the field of electrical and electronic equipment manufacturing.
  • Mark VIe Control System: The board is a part of the General Electric Mark VIe control system, which is a state-of-the-art control system used in a variety of industries to manage complex processes and systems.

Interface features

  • The controller's EGD pages are used to drive numeric data displays. The refresh rate is determined by how quickly the controller transmits pages and how quickly the COI refreshes fields. Both are configured in the toolbox during the configuration process. The COI operates on a touch screen, with no keyboard or mouse provided. State feedback conditions determine the color of pushbuttons.
  • Press the button to change the state or condition. If the command is accepted and the change is implemented by the controller, the color of the button changes. When you touch an input numeric field on the COI touch screen, a numeric keypad appears for you to enter the desired number.
  • An Alarm Window is provided, and by touching it, an alarm can be selected. Then, by pressing the corresponding button, you can acknowledge, silence, lock, or unlock the alarm. By dragging through the alarm list, you can select multiple alarms. When you press the button, it applies to all of the alarms you've chosen.

WOC is happy to assist you with any of your automation requirements. Please contact us by phone or email for pricing and availability on any parts and repairs.

FREQUENTLY ASKED QUESTIONS

What is IS200SCTLG1A?
It is a static control charge board developed by GE.

What kind of connectors does this board have?
The board has two sets of sub-D pin connectors, one with three pins and the other with four pins.

What are the redundancy levels that this board can operate at?
It operate at three different redundancy levels: single, dual, and triple.

What input packs are used when using the board with dual redundant systems?
When using the board with dual redundant systems, redundant and single input packs with dual IONets will be used to transmit the inputs to the Mark VIe controllers.

What is the fuse rating and mounting location of this board?
The fuse for this board has a rating of 120 VDC and is mounted in the load cabinet.