World Of Controls understands the criticality of your requirement and works towards reducing the lead time as much as possible.
5463-373 - High-Density Analog Input Module is available in stock which ships the same day.
5463-373 - High-Density Analog Input Module comes in UNUSED as well as REBUILT condition.
To avail our best deals for 5463-373 - High-Density Analog Input Module, contact us and we will get back to you within 24 hours.
TECHNICAL SPECIFICATIONS:
Part Number: 5463-373
Manufacturer: Woodward
Series: NetCon / MicroNet Series
Product Type: High-Density Analog Input Module
Channel Density: Multi-Channel Analog Inputs (0–20 mA, 4–20 mA, 0–5 V, 0–10 V configurable)
A/D Conversion Resolution: 16-Bit Precision Analog-to-Digital Processing
Sampling Rate: Fast Deterministic Update Cycle (< 5 ms per scan loop)
Input Impedance: 250
Accuracy Rating: Full Scale at 25°C
Isolation Barrier: 500 VDC Galvanic Channel-to-Logic Isolation
Power Supply Input: +5 VDC & $pm 15$ VDC (Supplied via Backplane)
Power Consumption: 6.0 W (Typical) / 8.5 W (Maximum)
Form Factor: Single-Slot Chassis Plug-in VME Card
Mounting Style: Standard VME / Chassis Backplane Slot Mount
Front Panel Display: Status LEDs (Power, Board Health, Channel Diagnostics)
Operating Temperature Limits: -40°C to +70°C (-40°F to +158°F)
Storage Temperature Range: -40°C to +85°C (-40°F to +185°F)
Relative Humidity Limit: 5% to 95% (Non-condensing)
Conformal Coating: Industrial Acrylic / Polyurethane PCB Protection
Vibration & Shock Standard: MIL-STD-810 & IEC 60068-2-6 Compliant
Repair Time: 3–7 Days
Availability: In Stock
Weight: Approximately 1.20 kg (2.65 lbs)
Country of Origin: United States
The 5463-373 is a High-Density Analog Input Module designed and manufactured by Woodward. Operating within NetCon and MicroNet digital control systems, it converts field analog telemetry such as fuel pressure, lube oil temperature, valve position feedback, and discharge pressure into high-resolution digital data. By delivering rapid, noise-filtered signal conversion to the system backplane, the Analog Input Module provides the essential process variables required for closed-loop turbine governing, load management, and safety interlock execution.
PRECISION SIGNAL CONVERSION & TRANSIENT NOISE REJECTION
Designed to handle critical process loops, the Analog Input Module features high-resolution 16-bit A/D converters that process incoming standard industrial signals with minimal signal drift. Internal hardware filtering and active common-mode rejection suppress high-frequency EMI, ground loops, and switching noise present in industrial plant environments. Channel-to-logic galvanic isolation safeguards core processor cards against field voltage spikes and surges, maintaining long-term measurement stability across varying operating temperatures.
ANALOG LOOP AUDITING & OUT-OF-BOUNDS SAFEGUARDS
The Analog Input Module continuously evaluates signal integrity across every active loop. The module detects open transmitter circuits, shorted loop supply lines, and out-of-range signal conditions in real time. Front-panel diagnostic indicators offer field technicians immediate channel health feedback. When a transmitter wire breaks or drops below valid current thresholds ($< 3.6text{ mA}$), the module alerts the primary CPU, allowing governor logic to freeze demand outputs or failover to redundant process transmitters without interrupting operation.
WHY BUY FROM WOC
World of Controls specializes in supplying, repairing, and maintaining critical Woodward control system hardware worldwide. Every Woodward Analog Input Module undergoes a comprehensive quality assurance process, including multi-point current/voltage calibration testing, line noise suppression verification, fault injection testing, and thermal burn-in under live chassis loads. We maintain ready-to-ship stock of UNUSED surplus and professionally REBUILT modules to assist plants in reducing unexpected downtime. Backed by expert technical support, warranty coverage, global shipping, and extensive Woodward system experience, WOC is your trusted source for turbine control solutions.
What is Woodward 5463-373?
The Woodward 5463-373 is a High-Density Analog Input Module used in NetCon and MicroNet control chassis. It samples analog field signals (such as 4–20 mA or 0–10 V transmitter loops) and provides clean, digitized process data to the central governor CPU for control and protection routines.
What types of field transmitters connect to the High-Density Analog Input Module?
The module interfaces with a wide variety of process sensors, including pressure transmitters, temperature transmitters, LVDT feedback conditioners, flow meters, and level sensors.
How does the Analog Input Module handle broken field wires or failed process transmitters?
The module features active loop auditing that identifies under-range conditions on a 4–20 mA loop. Upon detecting a loop fault, it flags a bad-quality signal status to the controller to prevent erroneous governor response.